Users must ensure that cooling does not become excessive, as condensation on the glass window can block IR detection.

The detector should be aligned vertically to achieve a position analog output near 50% of the range when the hot material is centered. id6100 danieli manual hot

The sensor body incorporates a cooling circuit that can be fed with air, water, or other fluids. If ambient temperatures exceed 40°C (104°F) , active cooling is required to prevent damage. Users must ensure that cooling does not become

Requires 24 VDC ± 20% with a consumption of roughly 7.2W. id6100 danieli manual hot

DANIELI AUTOMATION ID6100 INSTRUCTION MANUAL Pdf Download | ManualsLib. ManualsLib

The detector should be pointed downwards and screened from external light or IR sources to prevent signal noise. Signal Outputs and Connectivity